pH, ORP, and Titration, Combination Electrodes
- (4)
- (2)
- (2)
- (1)
- (3)
- (43)
- (2)
- (1)
- (9)
- (2)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (43)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (26)
- (7)
- (2)
- (1)
- (1)
- (1)
- (1)
- (24)
- (2)
- (2)
- (1)
- (1)
- (1)
- (5)
- (1)
- (1)
- (1)
- (1)
- (3)
- (35)
- (29)
- (1)
- (1)
- (98)
- (25)
- (2)
- (11)
- (7)
- (2)
- (3)
- (3)
- (4)
- (1)
- (2)
- (1)
- (3)
- (2)
- (1)
- (1)
- (1)
- (70)
- (3)
- (1)
- (24)
- (3)
- (1)
- (6)
- (5)
- (1)
- (2)
- (4)
- (16)
- (2)
- (1)
- (1)
- (1)
- (7)
- (1)
- (3)
- (2)
- (19)
- (9)
- (5)
- (1)
- (2)
- (1)
- (18)
- (8)
- (1)
- (6)
- (2)
- (1)
- (1)
- (6)
- (1)
- (2)
- (9)
- (2)
- (93)
- (36)
- (1)
- (2)
- (2)
- (2)
- (6)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (6)
- (2)
- (1)
- (1)
- (19)
- (1)
- (1)
- (7)
- (8)
- (5)
- (2)
- (4)
- (1)
- (1)
- (26)
- (1)
- (5)
- (3)
- (1)
- (20)
- (180)
- (1)
- (16)
- (2)
- (1)
- (3)
Filtered Search Results
Thermo Scientific™ Orion™ ROSS™ Combination Flat Surface pH Electrodes PROMO
When you purchase a Thermo Scientific™ ROSS™ pH Electrode, you’ll receive a ROSS Buffer Kit at no additional cost. Order using the catalog numbers below and your products will ship together.
| Temperature (English) Operating | 32 to 212°F |
|---|---|
| pH Range | 0 to 14 |
| Diameter (Metric) Cap | 16 mm |
| Material | Epoxy Body |
| Storage Requirements | Short-term Storage (up to one week): Soak the electrode in ROSS' pH electrode storage solution, Cat. No. 810001, or standard pH electrode storage solution, Cat. No. 910001. For enhanced electrode performance, use ROSS' pH electrode storage solution. Long-term Storage (more than one week): Fill the reference chamber and securely cover the fill hole. Cover the sensing bulb and reference junction with the protective cap, sleeve or storage bottle containing a few drops of storage solution. Before returning the electrode to use, prepare it as a new electrode. |
| Diameter (English) Body | 0.47 in. |
| Precision | 0.01 |
| For Use With (Equipment) | Standard pH Meter |
| Filling Solution Type | 3M KCl |
| Drift | <0.002 pH/day |
| Junction | Glass Fiber |
| Diameter (Metric) Body | 12 mm |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ROSS |
Thermo Scientific™ Orion™ 8103BNUWP ROSS Ultra™ pH Electrode PROMO
When you purchase a Thermo Scientific™ ROSS™ pH Electrode, you’ll receive a ROSS Buffer Kit at no additional cost. Order using the catalog numbers below and your products will ship together.
Thermo Scientific™ Orion™ ROSS Ultra™ Glass Triode™ pH/ATC Combination Electrodes PROMO
When you purchase a Thermo Scientific™ ROSS™ pH Electrode, you’ll receive a ROSS Buffer Kit at no additional cost. Order using the catalog numbers below and your products will ship together.
| Warranty | 2 Years |
|---|---|
| Length (Metric) Cable | 1 m |
| Length (Metric) | 120 mm |
| Isopotential Point | 7 |
| pH Range | 0 to 14 |
| Material | Glass Body |
| Type | pH/ATC Combination Electrode |
| Precision | 0.01 |
| Diameter (Metric) | 12 mm |
| Filling Solution Type | ROSS electrode 3 M KCl fill solution (Cat. No. 810007) |
| Junction | Ceramic |
| pH Relative Accuracy | 0.03 pH for buffers using automatic temperature compensation |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ROSS |
Thermo Scientific™ Orion™ 8135BNUWP ROSS Ultra™ pH Electrode PROMO
When you purchase a Thermo Scientific™ ROSS™ pH Electrode, you’ll receive a ROSS Buffer Kit at no additional cost. Order using the catalog numbers below and your products will ship together.
Thermo Scientific™ Orion™ 8104BNUWP ROSS Ultra™ pH Electrode PROMO
When you purchase a Thermo Scientific™ ROSS™ pH Electrode, you’ll receive a ROSS Buffer Kit at no additional cost. Order using the catalog numbers below and your products will ship together.
Thermo Scientific™ Orion™ 8104BNUWP ROSS Ultra™ pH Electrode
Obtain precise pH determinations and a toughened bulb for rugged lab use with the Thermo Scientific™ Orion™ 8104BNUWP ROSS Ultra™ pH Electrode.
Thermo Scientific™ Orion™ ROSS™ Combination Semi-micro pH Electrodes PROMO
When you purchase a Thermo Scientific™ ROSS™ pH Electrode, you’ll receive a ROSS Buffer Kit at no additional cost. Order using the catalog numbers below and your products will ship together.
| Description | Semi micro tip |
|---|---|
| Length (Metric) | 165 mm |
| Temperature (English) Operating | 32 to 212°F |
| pH Range | 0 to 14 |
| Diameter (Metric) Cap | 16 x 95 mm L |
| Length (English) | 6.5 in. |
| Material | Glass Body |
| Storage Requirements | To ensure a quick response and free flowing junction, the sensing bulb and reference junction must not dry out. Short-term Storage (up to one week): Soak the electrode in ROSS' pH electrode storage solution, Cat. No. 810001. Long Term Storage (more than one week): Fill the reference chamber and securely cover the fill hole. Cover the sensing bulb and reference junction with the protective cap, sleeve or storage bottle containing a few drops of storage solution. |
| Precision | 0.01 |
| For Use With (Equipment) | Standard pH Meter |
| Filling Solution Type | 3M KCl |
| Drift | <0.002 pH/day |
| Junction | Ceramic |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ROSS |
Thermo Scientific™ Orion™ ROSS Ultra™ Low Maintenance pH/ATC Triode™ Combination Electrodes PROMO
When you purchase a Thermo Scientific™ ROSS™ pH Electrode, you’ll receive a ROSS Buffer Kit at no additional cost. Order using the catalog numbers below and your products will ship together.
| Type | pH/ATC Combination Electrode |
|---|---|
| Warranty | 18 Months |
| Length (Metric) | 120 mm |
| Precision | 0.01 |
| Isopotential Point | 7 |
| pH Range | 0 to 14 |
| Diameter (Metric) | 12 mm |
| Filling Solution Type | None required |
| Material | Epoxy Body |
| Junction | Glass Capillary |
| pH Relative Accuracy | 0.03 pH for buffers using automatic temperature compensation |
| Temperature (Metric) Operating | 0°C to 80°C |
| Internal Reference | ROSS |
Sartorius Dual Platinum Karl Fischer Electrode
Insert into compression fitting cap of Model 275 Karl Fischer Titrator.
SI Analytics™ BlueLine Precision Electrode with Liquid Electrolyte
Universal, precise pH measurement for the laboratory
| Temperature (Metric) Range | -5°C to +100°C |
|---|---|
| pH Range | 0 to 14 |
| Diameter (Metric) | 12 mm |
| Membrane | Type A Glass |
| Filling Solution Type | 3 M KCl (Liquid) |
| Material | Glass |
| For Use With (Application) | pH Measurements in Laboratory Applications |
| Internal Reference | Ag/AgCl |
Fisherbrand™ accumet™ pH/ATC Combination Titration Electrode for AB, AR and XL Series Meters
Science Education
A science education product.
A science education product.
TRIS compatible, rugged, and convenient. For use with AB, AR and XL Series Meters.
Fisherbrand™ accumet™ Refillable Glass pH Electrode
Science Education
A science education product.
A science education product.
Used with AB15+ and AB15 kit for routine pH and titration measurements of aqueous solutions with small samples, small vessels.
Thermo Scientific™ Orion™ Basic Electrodes
Science Education
A science education product.
A science education product.
For basic pH measurements of common samples